Intensity-Modulated Radiotherapy of the Breast and Lung - CAM 80146

Description
Radiotherapy (RT) is an integral component of the treatment of breast and lung cancers. Intensity-modulated radiotherapy (IMRT) has been proposed as a method of RT that allows adequate radiation to the tumor while minimizing the radiation dose to surrounding normal tissues and critical structures.

For individuals who have breast cancer who receive IMRT, the evidence includes systematic reviews, RCTs, and nonrandomized comparative studies. Relevant outcomes are OS, locoregional control, quality of life, and treatment-related morbidity. There is modest evidence from RCTs for a decrease in acute skin toxicity with IMRT compared with 2D-RT for whole-breast irradiation, and dosimetry studies have demonstrated that IMRT reduces inhomogeneity of radiation dose, thus potentially providing a mechanism for reduced skin toxicity. However, because whole-breast RT is now delivered by 3D-CRT, these comparative data are of limited value.

Studies comparing IMRT with 3D-CRT include 1 RCT comparing IMRT with DIBH to 3D-CRT, 2 nonrandomized comparative studies on whole-breast IMRT, and a few studies on chest wall IMRT. These studies suggest that IMRT requires less radiation exposure to nontarget areas and may improve short-term clinical outcomes. The available studies on chest wall IMRT for postmastectomy breast cancer patients have only focused on treatment planning and techniques. However, when dose-planning studies have indicated that RT will lead to unacceptably high radiation doses, the studies suggest IMRT will lead to improved outcomes. The evidence is sufficient to determine that the technology results in a meaningful improvement in the net health outcome.

Evidence supports the use of IMRT for left-sided breast lesions in which alternative types of RT cannot avoid toxicity to the heart. Based on available evidence, input from clinical vetting, a strong chain of evidence, and the potential to reduce harms, IMRT may be considered medically necessary for whole-breast irradiation when (1) alternative forms of RT cannot avoid cardiac toxicity, and (2) IMRT dose-planning demonstrates a substantial reduction in cardiac toxicity. IMRT for the palliative treatment of lung cancer is considered not medically necessary because conventional radiation techniques are adequate for palliation.

For individuals who have lung cancer who receive IMRT, the evidence includes nonrandomized, retrospective, comparative studies. Relevant outcomes are OS, locoregional control, and treatment-related morbidity. Dosimetry studies have shown that IMRT can reduce radiation exposure to critical surrounding structures, especially in large lung tumors. Based on nonrandomized comparative studies, IMRT appears to produce survival outcomes comparable to those of 3D-CRT and reduce toxicity. The evidence is sufficient to determine that the technology results in a meaningful improvement in the net health outcome.

Clinical vetting also provided strong support for IMRT when alternative RT dosimetry exceeds a threshold of 20-Gy dose-volume (V20) to at least 35% of normal lung tissue. Based on available evidence, clinical vetting, a strong chain of evidence, and the potential to reduce harms, IMRT may be considered medically necessary for lung cancer when: (1) RT is given with curative intent, (2) alternative RT dosimetry demonstrates radiation dose exceeding V20 for at least 35% of normal lung tissue, and (3) IMRT reduces the V20 of radiation to the lung at least 10% below the V20 of 3D-CRT (e.g., 40% reduced to 30%).

Background
For certain stages of many cancers, including breast and lung, randomized controlled trials have shown that postoperative radiotherapy (RT) improves outcomes for operable patients. Adding radiation to chemotherapy also improves outcomes for those with inoperable lung tumors that have not metastasized beyond regional lymph nodes.

RADIOTHERAPY TECHNIQUES
Conventional External-Beam Radiotherapy
Methods to plan and deliver RT have evolved in ways that permit more precise targeting of tumors with complex geometries. Most early trials used 2-dimensional treatment planning, based on flat images and radiation beams with cross-sections of uniform intensity that were sequentially aimed at the tumor along two or three intersecting axes. Collectively, these methods are termed conventional external-beam  radiotherapy.

Three-Dimensional Conformal Radiotherapy
Treatment planning evolved by using 3-dimensional images, usually from computed tomography (CT) scans, to delineate the boundaries of the tumor and discriminate tumor tissue from adjacent normal tissue and nearby organs at risk for radiation damage. Computer algorithms were developed to estimate cumulative radiation dose delivered to each volume of interest by summing the contribution from each shaped beam. Methods also were developed to position the patient and the radiation portal reproducibly for each fraction and immobilize the patient, thus maintaining consistent beam axes across treatment sessions. Collectively, these methods are termed 3-dimensional conformal radiotherapy (3D-CRT).

Intensity-Modulated Radiotherapy
IMRT, which uses computer software along with CT and magnetic resonance imaging images, offers better conformality than 3D-CRT because it modulates the intensity of the overlapping radiation beams projected on the target and uses multiple shaped treatment fields. Treatment planning and delivery are more complex, time-consuming, and labor-intensive for IMRT than for 3D-CRT. The technique uses a multi-leaf collimator (MLC), which, when coupled with a computer algorithm, allows for "inverse" treatment planning. The radiation oncologist delineates the target on each slice of a CT scan and specifies the target’s prescribed radiation dose, acceptable limits of dose heterogeneity within the target volume, adjacent normal tissue volumes to avoid, and acceptable dose limits within the normal tissues. Based on these parameters and a digitally reconstructed radiographic image of the tumor, surrounding tissues, and organs at risk, computer software optimizes the location, shape, and intensities of the beam ports to achieve the treatment plan’s goals.

Increased conformality may permit escalated tumor doses without increasing normal tissue toxicity and thus may improve local tumor control, with decreased exposure to surrounding, normal tissues, potentially reducing acute and late radiation toxicities. Better dose homogeneity within the target may also improve local tumor control by avoiding underdosing within the tumor and may decrease toxicity by avoiding overdosing.

Technologic developments have produced advanced techniques that may further improve RT treatment by improving dose distribution. These techniques are considered variations of IMRT. Volumetric modulated arc therapy delivers radiation from a continuous rotation of the radiation source. The principal advantage of volumetric modulated therapy is its efficiency in treatment delivery time, reducing radiation exposure and improving target radiation delivery due to less patient motion. Image-guided RT involves the incorporation of imaging before and/or during treatment to deliver RT to the target volume more precisely.

IMRT methods to plan and deliver RT are not uniform. IMRT may use beams that remain on as MLCs move around the patient (dynamic MLC) or that are off during movement and turn on once the MLC reaches prespecified positions ("step and shoot" technique). A third alternative uses a very narrow single beam that moves spirally around the patient (tomotherapy). Each method uses different computer algorithms to plan treatment and yields somewhat different dose distributions in and outside the target. Patient position can alter target shape and thus affect treatment plans. Treatment plans are usually based on one imaging scan, a static 3D-CT image. Current methods seek to reduce positional uncertainty for tumors and adjacent normal tissues by various techniques. Patient immobilization cradles and skin or bony markers are used to minimize day-to-day variability in patient positioning. In addition, many tumors have irregular edges that preclude drawing tight margins on CT scan slices when radiation oncologists contour the tumor volume. It is unknown whether omitting some tumor cells or including some normal cells in the resulting target affects outcomes of IMRT.

Investigators are exploring an active breathing control device combined with moderately deep inspiration breath-holding techniques to improve conformality and dose distributions during IMRT for breast cancer.1,2 Techniques presently being studied with other tumors (e.g., lung cancer)3 either gate beam delivery to the patient’s respiratory movement or continuously monitor tumor (by in-room imaging) or marker (internal or surface) positions to aim radiation more accurately at the target. The impact of these techniques on outcomes of 3D-CRT or IMRT for breast cancer is unknown. However, it appears likely that respiratory motion alters the dose distributions actually delivered while treating patients from those predicted by plans based on static CT scans or measured by dosimetry using stationary (nonbreathing) targets.

Regulatory Status 
In general, IMRT systems include intensity modulators, which control, block or filter the intensity of radiation; and RT planning systems, which plan the radiation dose to be delivered.

A number of intensity modulators have received marketing clearance through the U.S. Food and Drug Administration (FDA) 510(k) process. Intensity modulators include the Innocure Intensity Modulating Radiation Therapy Compensators (Innocure) decimal tissue compensator (Southeastern Radiation Products): FDA product code: IXI. Intensity modulators may be added to standard linear accelerators to deliver IMRT when used with proper treatment planning systems.

RT treatment planning systems have also received FDA 510(k) marketing clearance. These include the Prowess Panther (Prowess), TiGRT (LinaTech), Ray Dose (Ray Search Laboratories) and the eIMRT Calculator (Standard Imaging). FDA product code: MUJ.

Fully integrated IMRT systems also are available. These devices are customizable and support all stages of IMRT delivery, including planning, treatment delivery and health record management. One such device to receive FDA 510(k) clearance is the Varian IMRT system (Varian Medical Systems). FDA product code: IYE.

Related Policies
80147 Intensity-Modulated Radiotherapy of the Prostate
80148 Intensity-Modulated Radiotherapy: Cancer of the Head and Neck or Thyroid
80149 Intensity-Modulated Radiation Therapy (IMRT): Abdomen and Pelvis
80159 Intensity-Modulated Radiotherapy: Central Nervous System Tumors

Policy:
Intensity-modulated radiation therapy (IMRT) may be considered MEDICALLY NECESSARY as a technique to deliver whole-breast irradiation in patients receiving treatment for  breast cancer after breast-conserving surgery when all the following conditions have been met:

  • Significant cardiac radiation exposure cannot be avoided using alternative radiation techniques
  • IMRT dosimetry demonstrates significantly reduced cardiac target volume radiation exposure (See Policy Guidelines)

Intensity-modulated radiation therapy (IMRT) may be considered MEDICALLY NECESSARY in individuals with large breasts when treatment planning with 3-D conformal results in hot spots (focal regions with dose variation greater than 10 percent of target) and the hot spots are able to be avoided with IMRT (See Policy Guidelines).

Intensity-modulated radiation therapy (IMRT) of the breast is investigational and/ or unproven and therefore considered NOT MEDICALLY NECESSARY as a technique of partial-breast irradiation after breast-conserving surgery.

Intensity-modulated radiation therapy (IMRT) of the chest wall is  investigational and/ or unproven and therefore considered NOT MEDICALLY NECESSARY as a technique of postmastectomy irradiation.

Intensity-modulated radiation therapy (IMRT) may be considered MEDICALLY NECESSARY as a technique to deliver radiation therapy in patients with lung cancer when all of the following conditions are met:

  • Radiation therapy is being given with curative intent
  • 3-D conformal will expose > 35 percent of normal lung tissue to more than 20 Gy dose-volume (V20)
  • IMRT dosimetry demonstrates reduction in the V20 to at least 10 percent below the V20 that is achieved with the 3-D plan (e.g., from 40 percent down to 30 percent or lower)

Intensity-modulated radiation therapy (IMRT) is considered NOT MEDICALLY NECESSARY as a technique to deliver radiation therapy in patients receiving palliative treatment for lung cancer.

IMRT is NOT MEDICALLY NECESSARY for the treatment of breast or lung cancer for all indications not meeting the criteria above.

Policy Guidelines
Table PG1 outlines radiation doses generally considered tolerance thresholds for these normal structures for the chest and abdomen. Dosimetry plans may be used to demonstrate that radiation by 3-dimensional conformal radiotherapy (3D-CRT) would exceed tolerance doses to structures at risk. 

Table PG1. Radiation Tolerance Doses for Normal Tissues of the Chest and Abdomen   

Site 

TD 5/5, Graya

TD 50/5, Grayb

Complication End Point

 

Portion of organ involved

Portion of organ involved

 
 

1/3

2/3

3/3

1/3

2/3

3/3

 
Heart   60   45   40   70   55   50   Pericarditis  
Lung   45   30   17.5   65   40   24.5   Pneumonitis  
Spinal cord   50   50   47   70   70   NP   Myelitis, necrosis  

Compiled from: (1) Morgan MA (2011). Radiation oncology. In DeVita, Lawrence, and Rosenberg, Cancer (p.308). Philadelphia: Lippincott Williams and Wilkins; and (2) Kehwar TS, Sharma SC. Use of normal tissue tolerance doses into linear quadratic equation to estimate normal tissue complication probability. Available at: http://www.rooj.com/Radiation%20Tissue%20Tolerance.htm. NP: not provided; TD: tolerance dose
a TD 5/5 is the average dose that results in a 5% complication risk within 5 years.
b TD 50/5 is the average dose that results in a 50% complication risk within 5 years.  

The following is an example of clinical guidelines that may be used with intensity-modulated radiotherapy (IMRT) in left-sided breast lesions:

  • The target volume coverage results in cardiac radiation exposure that is expected to be greater than or equal to 25 gray (Gy) to 10 cm3 or more of the heart (V25 ≥10 cm3) with 3D-CRT, despite the use of a complex positioning device (e.g., Vac-Lok), and
  • With the use of IMRT, there is a reduction in the absolute heart volume receiving 25 Gy or more by at least 20% (e.g., volume predicted to receive 25 Gy by 3D-CRT is 20 cm3, and the volume predicted by IMRT is ≤16 cm3).

The following are examples of criteria to define large breast size when using IMRT to avoid hot spots, as derived from randomized studies:

  • Donovan et al. (2007) enrolled patients with "higher than average risk of late radiotherapy-adverse effects," which included patients having larger breasts. The authors stated that while breast size is not particularly good at identifying women with dose inhomogeneity falling outside current International Commission on Radiation Units and Measurements guidelines, they excluded women with small breasts (≤500 cm3), who generally have fairly good dosimetry with standard 2-dimensional compensators.
  • In the trial by Pignol et al. (2008), which reported that the use of IMRT significantly reduced the proportion of patients experiencing moist desquamation, breast size was categorized as small, medium, or large by cup size. Multivariate analysis found that smaller breast size was significantly associated with a decreased risk of moist desquamation (p<0.001).

CODING
The following CPT codes are used for simple and complex IMRT delivery:

77385 Intensity modulated radiation treatment delivery (IMRT), includes guidance and tracking, when performed; simple
77386 Complex.

The Centers for Medicare & Medicaid Services did not implement these CPT codes and instead created HCPCS G codes with the language of the previous CPT codes. Therefore, the following codes may be used for IMRT:

G6015 Intensity modulated treatment delivery, single or multiple fields/arcs, via narrow spatially and temporally modulated beams, binary, dynamic MLC, per treatment session 

G6016 Compensator-based beam modulation treatment delivery of inverse planned treatment using 3 or more high resolution (milled or cast) compensator, convergent beam modulated fields, per treatment session.

Code 77301 (Intensity-modulated radiotherapy plan, including dose-volume histograms for target and critical structure partial tolerance specifications) remains valid.

The following CPT code may also be used and is to be reported only once per IMRT plan:

77338 Multi-leaf collimator (MLC) device(s) for intensity-modulated radiation therapy (IMRT), design and construction per IMRT plan

Benefit Application
BlueCard/National Account Issues
State or federal mandates (e.g., FEP) may dictate that all devices approved by the U.S. Food and Drug Administration (FDA) may not be considered investigational, and, thus, these devices may be assessed only on the basis of their medical necessity.

For contracts that do not use this definition of medical necessity, other contract provisions, including contract language concerning use of out of network providers and services, may be applied. That is, if the alternative therapies (e.g., 3-D-conformal treatments) are available in-network but IMRT therapy is not, IMRT would not be considered an in-network benefit. In addition, benefit or contract language describing the "least costly alternative" may also be applicable for this choice of treatment.

Rationale 
This evidence review was created in December 2005 and has been regularly updated with searches of the PubMed database. The most recent literature update was performed through May 25, 2021.

Evidence reviews assess the clinical evidence to determine whether the use of a technology improves the net health outcome. Broadly defined, health outcomes are the length of life, quality of life, and ability to function-including benefits and harms. Every clinical condition has specific outcomes that are important to patients and to managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.

To assess whether the evidence is sufficient to draw conclusions about the net health outcome of a technology, 2 domains are examined: the relevance and the quality and credibility. To be relevant, studies must represent 1 or more intended clinical use of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The randomized controlled trial (RCT) is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. Randomized controlled trials are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice.

Multiple-dose planning studies generate 3-dimensional (3D) conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) treatment plans from the same scans and then compare predicted dose distributions within the target area and adjacent organs. Results of such planning studies have shown that IMRT is better than 3D-CRT with respect to conformality to, and dose homogeneity within, the target. Results have also demonstrated that IMRT delivers less radiation to nontarget areas. Dosimetry studies using stationary targets generally confirm these predictions. However, because patients move during treatment, dosimetry with stationary targets only approximate actual radiation doses received. Based on these dosimetry studies, radiation oncologists expect IMRT to improve treatment outcomes compared with those of 3D-CRT.

Comparative studies of radiation-induced adverse events from IMRT versus alternative radiation delivery would constitute definitive evidence of establishing the benefit of IMRT. Single-arm series of IMRT can give insights into the potential for benefit, particularly if an adverse event that is expected to occur at high rates is shown to decrease by a large amount. Studies of treatment benefit are also important to establish that IMRT is at least as good as other types of delivery, but, absent such comparative trials, it is likely that the benefit from IMRT is at least as good as with other types of delivery.

In general, when the indication for IMRT is to avoid radiation to sensitive areas, dosimetry studies have been considered sufficient evidence to demonstrate that harm would be avoided by using IMRT. For other indications, such as using IMRT to provide better tumor control, comparative studies of health outcomes are needed to demonstrate such a benefit.

Breast Cancer
Clinical Context and Therapy Purpose
The purpose of the use of IMRT in patients who have breast cancer is to provide a treatment option that is an alternative to or an improvement on existing therapies.

The question addressed in this evidence review is: Does the use of IMRT improve the net health outcome in patients with breast cancer?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is women with breast cancer.

Interventions
The therapy being considered is IMRT. Radiotherapy (RT) is an integral component of the treatment of breast cancer; IMRT has been proposed as a method of RT that allows adequate radiation to the tumor while minimizing the radiation dose to surrounding normal tissues and critical structures.

Comparators
The following therapy is currently being used to make decisions about breast cancer: 2-dimensional (2D) and 3D-CRT.

Outcomes
The general outcomes of interest are overall survival (OS), disease-specific survival, locoregional control, quality of life, and treatment-related adverse events (e.g., radiation dermatitis).

The grading of acute radiation dermatitis is relevant to studies of IMRT for the treatment of breast cancer. Acute radiation dermatitis is graded on a scale of 0 (no change) to 5 (death). Grade 2 is moderate erythema and patchy moist desquamation, mostly in skin folds; grade 3 is moist desquamation in other locations and bleeding with minor trauma. Publications have also reported on the potential for IMRT to reduce radiation to the heart (left ventricle) in patients with left-sided breast cancer and unfavorable cardiac anatomy.6 This is a concern because of the potential development of late cardiac complications (eg, coronary artery disease) following fractionated radiotherapy (FRT) to the left breast.

In addition, IMRT may reduce toxicity to structures adjacent to tumors, allowing dose escalation to the target area and fewer breaks in treatment courses due to a reduction in side effects. However, this may come with a loss of locoregional control and OS.

Follow-up after IMRT varies by the staging of breast cancer and patient age at diagnosis. Five-year to 10-year follow-up to monitor for recurrence have been recommended.

Study Selection Criteria
Methodologically credible studies were selected using the following principles: 

  • To assess efficacy outcomes, comparative controlled prospective trials were sought, with a preference for RCTs.

  • In the absence of such trials, comparative observational studies were sought, with a preference for prospective studies.

  • To assess long-term outcomes and adverse events, single-arm studies that capture longer periods of follow-up and/or larger populations were sought.

  • Studies with duplicative or overlapping populations were excluded.

Review of Evidence
Whole-Breast Irradiation With Intensity-Modulated Radiotherapy Versus 2-Dimensional Radiotherapy
Systematic Reviews
Dayes et al. (2012) conducted a systematic review of the evidence for IMRT for whole-breast irradiation in the treatment of breast cancer to quantify its potential benefits and to make recommendations for radiation treatment programs.7 Based on a review of 6 studies (N = 2012 patients) published through March 2009 (1 RCT, 3 retrospective cohort studies, 1 historically controlled trial, 1 prospective cohort), reviewers recommended IMRT over conventional RT after breast-conserving surgery to avoid acute adverse events associated with radiation. There were insufficient data to recommend IMRT over conventional RT based on oncologic outcomes or late toxicity. The RCT included in this review was the Canadian multicenter trial by Pignol et al (2008), details of which are reported in the next section.2 In this RCT, IMRT was compared with 2D-RT. Computed tomography (CT) scans were used in treatment planning for both arms of the study. The types of conventional RT regimens used in the other studies were not reported.

Randomized Controlled Trials
Donovan et al. (2007) evaluated IMRT as compared to 2D-RT (using standard wedge compensators) regarding late adverse effects after whole breast RT.1 Enrolled patients had a "higher than average risk of late radiotherapy-adverse effects," which included patients with larger breasts. Trialists stated that while breast size was not particularly good at identifying women with dose inhomogeneity falling outside current International Commission on Radiation Units and Measurements guidelines, their trial excluded women with small breasts (≤ 500 cm3), who generally have fairly good dosimetry with standard 2D compensators. All patients were treated with 6 or 10 megavolt photons to a dose of 50 gray (Gy) in 25 fractions in 5 weeks followed by an electron boost to the tumor bed of 11.1 Gy in 5 fractions. The primary endpoint (change in breast appearance) was scored from serial photographs taken before RT and at 1-, 2-, and 5-year follow-ups. Secondary endpoints included patient self-assessments of breast discomfort, breast hardness, quality of life, and physician assessments of breast induration. Two hundred forty (79%) patients with 5-year photographs were available for analysis. Change in breast appearance was identified in 71 (58%) of 122 patients allocated standard 2D treatment compared with 47 (40%) of 118 patients allocated IMRT. Significantly fewer patients in the IMRT group developed palpable induration assessed clinically in the center of the breast, pectoral fold, inframammary fold, and at the boost site. No significant differences between treatment groups were found in patient-reported breast discomfort, breast hardness, or quality of life. The authors concluded that minimization of unwanted radiation dose inhomogeneity in the breast reduced late adverse events. While the change in breast appearance differed statistically, a beneficial effect on quality of life was not demonstrated.

The multicenter, double-blind RCT by Pignol et al. (2008, 2016) evaluated whether breast IMRT would reduce the rate of acute skin reaction (moist desquamation), decrease pain, and improve quality of life compared with 2D-RT using wedges.2,8 Patients were assessed each week up to 6 weeks after RT and then at 8 to 10 years. A total of 358 patients were randomized between 2003 and 2005 at 2 Canadian centers, and 331 were analyzed. Of these, 241 patients were available for long-term follow-up. The trialists noted that breast IMRT significantly improved dose distribution compared with 2D-RT. They also noted a lower proportion of patients with moist desquamation during or up to 6 weeks after RT (31% with IMRT vs. 48% with standard treatment; p =.002). A multivariate analysis found the use of breast IMRT and smaller breast size were significantly associated with a decreased risk of moist desquamation. The presence of moist desquamation significantly correlated with pain and a reduced quality of life. At a median follow-up of 9.8 years, there was no significant difference in chronic pain between treatment arms. Young age (p =.013) and pain during RT (p < .001) were associated with chronic pain. Poorer self-assessed cosmetic outcome (p < .001) and quality of life (p < .001) were also associated with pain during RT.

Barnett et al. (2009) published baseline characteristics and dosimetry results of a single-center RCT assessing IMRT for early breast cancer after breast-conserving surgery.9 Subsequently, Barnett et al. (2012) reported on the 2-year interim results of this RCT.10 In this trial, 1145 patients with early breast cancer were evaluated for external-beam RT. Twenty-nine percent had adequate dosimetry with standard RT. The other 815 patients were randomized to IMRT or 2D-RT. Inhomogeneity occurred most often when the dose-volume was greater than 107% (V107) of the prescribed dose to a breast volume greater than 2 cm3 with conventional RT. When breast separation was 21 cm or more, 90% of patients had received greater than V107 of the prescribed dose to greater than 2 cm3 with standard radiation planning. The incidence of acute toxicity did not differ significantly between groups. Additionally, photographic assessment scores for breast shrinkage did not differ significantly between groups. The authors noted overall cosmesis after 2D-RT and IMRT was dependent on surgical cosmesis, suggesting breast shrinkage and induration were due to surgery rather than radiation, thereby masking the potential cosmetic benefits of IMRT.

Whole-Breast Irradiation With Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy
Randomized Controlled Trials
In their RCT, Jagsi et al. (2018)4 assessed whether IMRT with deep inspiration breath hold (DIBH) reduces cardiac or pulmonary toxicity of breast RT compared to 3D-CRT. The study included 62 women with node-positive breast cancer in whom RT was indicated for treating the left breast or chest wall and the internal mammary, infraclavicular, and supraclavicular nodal regions. The primary outcome was the percentage decrease in heart perfusion at 1 year post-treatment compared to baseline, measured using attenuation corrected single-photon emission CT. A secondary outcome was a change in left ventricular ejection fraction. The 3D-CRT group received ≥ 5 Gy to 15.8% of the left ventricle; the IMRT-DIBH group received 5.6% to the left ventricle (p <.001). At 1 year, no differences in perfusion of the heart were detected; however, significant differences were found in left ventricular ejection fraction. In the 3D-CRT arm, 6 patients had > 5% changes in left ventricular ejection fraction, and the IMRT-DIBH arm had 1 patient with > 5% change. The authors contend that their study is important because it demonstrates that the IMRT-DIBH technique’s reduction in cardiac dose could be associated with better preservation of cardiac left ventricle function—a potentially clinically meaningful finding. One limitation of this study is its small size, and only 1 follow-up scan was conducted at 1 year due to resource constraints. A 6-month scan might have shown greater differences between the 2 arms. 

Choi et al. (2021) compared disease control and safety of IMRT compared to 3D-CRT in a multicenter, phase III, open-label, randomized (1:1) trial enrolling 693 women who had undergone breast-conserving surgery for breast cancer staging pT1-2N0M0 with a negative resection margin in Korea.11 The 3D-CRT group received 50.4 Gy in 28 fractions on the ipsilateral breast with additional 9 Gy in 5 fractions on the tumor bed for 6.5 weeks. In the IMRT group, patients received 50.4 Gy in 28 fractions on the ipsilateral breast with a simultaneous integrated boost of 57.4 Gy in 28 fractions on the tumor bed for 5.5 weeks. The primary endpoint was 3-year locoregional recurrence-free survival; secondary endpoints included recurrence-free survival, distant metastasis-free survival, OS, acute toxicity, irradiation dose to organs at risk, and fatigue inventory. Results revealed a 3-year locoregional recurrence-free survival rate of 99.4% in the 3D-CRT arm versus 98.5% in the IMRT arm (p =.523). Similarly, there was no statistically significant difference between the groups in 3-year distant metastasis-free survival (98.8% 3D-CRT vs. 99.6% IMRT; p =.115), recurrence-free survival (97.4% vs. 98.2%; p =.418), or OS (99.6% vs. 100%; p =.165). Regarding toxicity, grade 2 or higher radiation dermatitis occurred less frequently in the IMRT arm (37.1% vs. 27.8%; p =.009). Fatigue was observed in 97.7% of patients in the 3D-CRT arm versus 98.5% of patients in the IMRT arm using a brief fatigue inventory survey. The mean lung dose and V5-V50 for the ipsilateral lung were significantly lower in the IMRT arm than the 3D-CRT arm (all p <.05).

Horner-Rieber et al. (2021) evaluated the effects of conventional fractionated IMRT with simultaneous integrated boost to 3D-CRT with sequential boost in the prospective, multicenter, randomized, noninferiority, phase III, IMRT-MC2 trial.12 This trial enrolled 502 patients with breast cancer treated with breast-conserving surgery followed by adjuvant whole-breast irradiation with boost irradiation to the lumpectomy cavity. The IMRT group received a total dose of 50.4 Gy in 1.8 Gy daily fractions with a simultaneous integrated boost to the tumor bed, for a total dose of 64.4 Gy. The 3D-CRT group received a total dose of 50.4 Gy in 1.8 Gy daily fractions, followed by a sequential boost to a total dose of 66.4 Gy. Overall treatment times were 1 to 1.6 weeks shorter in the IMRT-simultaneous integrated boost arm as compared with the 3D-CRT-sequential boost arm. After a median follow-up of 5.1 years, results revealed noninferiority between the IMRT and 3D-CRT groups with regard to 2-year local control rate: 99.6% in both arms (hazard ratio [HR], 0.602; 95% confidence interval [CI], 0.123 to 2.452; p =.487). Additionally, noninferiority was seen for cosmesis (according to relative breast retraction assessment score) after IMRT and 3D-CRT at both 6 weeks and 2 years after RT (p =.332). Overall survival rates were also not significantly different between the groups (99.6% for both arms; HR, 3.281; 95% CI, -0.748 to 22.585; p =.148). The authors concluded that clinical outcomes between the groups were similar with a considerably shortened treatment time for the IMRT approach. In a separate published analysis of the IMRT-MC2 trial focused on acute toxicity13, there were no significant differences between the groups with regard to any grade radiation dermatitis at the end of treatment (p =.26). However, Grade 2/3 radiation dermatitis (29.1% vs. 20.1% and 3.5% vs. 2.3%) occurred significantly more often in the IMRT arm (p =.02). Significantly more patients in the 3D-CRT arm experienced breast/chest wall pain at the initial follow-up visit (p =.02).

Nonrandomized Comparative Studies
Hardee et al. (2012) compared the dosimetric and toxicity outcomes after treatment with IMRT or 3D-CRT for whole-breast irradiation in 97 consecutive patients with early-stage breast cancer, who were assigned to either approach after partial mastectomy based on insurance carrier approval for reimbursement for IMRT.14 Intensity-modulated radiotherapy significantly reduced the maximum radiation dose to the breast (Dmax median, 110% for 3D-CRT vs. 107% for IMRT; p <.001) and improved median dose homogeneity (median, 1.15 for 3D-CRT vs. 1.05 for IMRT; p <.001) compared with 3D-CRT. These dosimetric improvements were seen across all breast volume groups. Grade 2 dermatitis occurred in 13% of patients in the 3D-CRT group and in 2% in the IMRT group. Intensity-modulated radiotherapy moderately decreased rates of acute pruritus (p =.03) and grade 2 and 3 subacute hyperpigmentation (p =.01). With a minimum of 6 months of follow-up, the treatment was reported to be similarly well-tolerated by both groups, including among women with large breast volumes.

Guttmann et al. (2018) published a single-center retrospective analysis of 413 women who received tangential whole-breast irradiation between 2011 and 2015 (Table 1).15 Of the patients, 212 underwent IMRT and 201 received 3D-CRT. The main endpoint was a comparison of acute radiation dermatitis (grade 2+), and secondary endpoints were acute fatigue and breast pain. Grade 2+ radiation dermatitis was experienced by 59% of 3D-CRT patients and 62% of IMRT patients (p =.09). There was also no significant difference between 3D-CRT and IMRT for breast pain (grade 2+, 18% vs. 18%, respectively; p =.33) or fatigue (grade 2+, 18% vs. 25.5%, respectively; p =.24) (Table 2). A study limitation was that follow-up varied across patients because those treated with IMRT completed treatment 1 week sooner than those treated with 3D-CRT.

Table 1. Summary of Key Nonrandomized Trials Characteristics 

Study Study Type Country Dates Participants Treatment Comparator FU
Guttmann et al. (2018)15 Retrospective U.S. 2011-2015 413 IMRT 3D-CRT 90 d

3D-CRT: 3-dimensional conformal radiotherapy; FU: follow-up; IMRT: intensity-modulated radiotherapy.

Table 2. Summary of Key Nonrandomized Trials Results 

Study Acute Radiation Dermatitis Acute Fatigue Acute Breast Pain
Guttmann et al. (2018)15    
IMRT      
N 212 212 212
Grade
  • Grade 0 = 1
  • Grade 1 = 78
  • Grade 2 = 129
  • Grade 3 = 3
  • Grade 0 = 46
  • Grade 1 = 127
  • Grade 2 = 39
  • Grade 3 = 0
  • Grade 0 = 26
  • Grade 1 = 127
  • Grade 2 = 39
  • Grade 3 = 0
3D-CRT      
N 201 201 201
Grade
  • Grade 0 = 0
  • Grade 1 = 83
  • Grade 2 = 109
  • Grade 3 = 9
  • Grade 0 = 44
  • Grade 1 = 121
  • Grade 2 = 33
  • Grade 3 = 3
  • Grade 0 = 44
  • Grade 1 = 121
  • Grade 2 = 33
  • Grade 3 = 3
p .09 .24 .33

3D-CRT: 3-dimensional conformal radiotherapy; IMRT: intensity-modulated radiotherapy. 

Chest Wall Irradiation
Studies have examined the use of IMRT for chest wall irradiation in postmastectomy breast cancer patients. Available studies have focused on treatment planning and techniques to improve dose distributions to targeted tissues while reducing radiation to normal tissue and critical surrounding structures (e.g., heart, lung). In a study by Rudat et al. (2011), treatment planning for chest wall irradiation with IMRT was compared with 3D-CRT in 20 postmastectomy patients.16 The authors reported IMRT significantly decreased heart and lung high-dose volume with a significantly improved conformity index compared with 3D-CRT. However, there were no significant differences in the homogeneity index. The authors noted longer-term prospective studies are needed to further assess cardiac toxicity and secondary lung cancer risk with multifield IMRT, which while reducing high-dose volume, increases mean heart and lung dose. As noted, health outcomes were not reported in this study.

Rastogi et al. (2018) published a retrospective study of 107 patients receiving RT postmastectomy to the left chest wall.17 Patients were treated with 3D-CRT (n = 64) or IMRT (n = 43). The planning target volume, homogeneity index, and conformity index for both groups were compared. Intensity-modulated radiotherapy had a significantly improved conformity index score (1.127) compared with 3D-CRT (1.254; p <.001), while results for both planning target volume (IMRT, 611.7 vs. 3D-CRT, 612.2; p = .55) and homogeneity index (IMRT, 0.094 vs. 3D-CRT, 0.096; p =.83) were comparable. Furthermore, secondary analyses showed that IMRT had significantly lower mean- and high-dose volumes to the heart and ipsilateral lung (p <.001 and p <.001, respectively), while 3D-CRT had superior low-dose volume (p < .001). The study was limited by its small population size and short follow-up.

Ho et al. (2019) published the long-term pulmonary outcomes of a feasibility study of inverse-planned, multibeam IMRT in node-positive breast cancer patients receiving regional nodal irradiation.18 While the authors' primary endpoint was feasibility, they also observed the incidence of radiation pneumonitis grade 3 or greater and changes in pulmonary function. The later endpoints were measured with the Common Terminology Criteria for Adverse Events and pulmonary function tests and community-acquired pneumonia questions. Of 104 completed follow-up procedures, the overall rate of respiratory toxicity was 10.6%, with 1 grade 3 radiation pneumonitis event.

Kivanc et al. (2019)19 published a dosimetric comparison of 3D-CRT and IMRT for left-sided chest wall and lymphatic irradiation. The study compared 5 different techniques (ie, 3D-CRT, forward-planned IMRT, inverse-planned IMRT [7- or 9-field], and hybrid inverse-planned/forward-planned IMRT) in 10 patients. Results revealed no differences among the techniques for doses received by 95% of the volume (D95%) of lymphatics. Forward-planned IMRT was associated with a significantly lower D95% dose to the chest wall-planning target volume as compared to the other techniques (p =.002). Of the evaluated techniques, the 9-field inverse-planned IMRT achieved the lowest volumes receiving higher doses. Overall, the dose homogeneity in chest wall-clinical target volume was improved with IMRT techniques versus 3D-CRT, especially 9-field inverse-planned IMRT. The hybrid IMRT plans had the advantages of both forward-planned and inverse-planned IMRT techniques.

Zhao et al. (2021) retrospectively evaluated differences in survival rate, recurrence, and late adverse effects in 223 patients with clinical stage II to III breast cancer who underwent a modified radical mastectomy, had positive axillary lymph nodes, and received either IMRT of the chest wall and regional nodes contoured as a whole planning target volume (n = 129) or conventional segmented 3D-CRT (n = 94).20 The mean follow-up of the study was 104.3 months. The 8-year disease-free survival rates were significantly improved in the IMRT group (86% vs. 73.4%; p =.022); however, the OS rates were not significantly different between the groups (91.4% IMRT vs. 86.2% 3D-CRT; p =.530). The number of patients that suffered from chronic skin toxicity was 96 in the IMRT arm and 73 in the 3D-CRT arm (p =.577), with most patients experiencing grade 1 to 2 skin reactions. Similarly, there were no significant differences between the groups with regard to other late adverse effects including grade 1 to 2 ipsilateral lung injury (30.2% IMRT vs. 31.9% 3D-CRT; p =.788) and grade 1 to 2 ipsilateral shoulder mobility (46.5% IMRT vs. 47.9% 3D-CRT; p =.841). Additionally, the percentages of patients with left breast cancer who suffered from grade 1 to 2 cardiac injury in the IMRT and 3D-CRT groups were 30.6% and 25.3%, respectively.

Section Summary: Breast Cancer
There is evidence from RCTs that IMRT decreases acute skin toxicity more than 2D-RT for whole-breast irradiation. One RCT reported improvements in moist desquamation of skin but did not find differences in grade 3 or 4 skin toxicity, pain symptoms, or quality of life. Another RCT found a change in breast appearance but not quality of life. A third RCT reported no differences in cosmetic outcomes at 2 years for IMRT or 2D-RT. Dosimetry studies have demonstrated that IMRT reduces inhomogeneity of radiation dose, thus potentially providing a mechanism for reduced skin toxicity. However, because whole-breast RT is now delivered by 3D-CRT, these comparison data are of limited value.

Studies comparing IMRT with 3D-CRT include 1 RCT comparing IMRT with DIBH to 3D-CRT, 2 additional RCTs comparing IMRT to 3D-CRT in women who had undergone breast-conserving surgery (with 1 RCT evaluating simultaneous vs. sequential boost therapy), 2 nonrandomized comparative assessments of whole-breast IMRT, and studies on treatment planning for chest wall IMRT. These studies have suggested that IMRT might improve upon, or provide similar improvement in, clinical outcomes. The risk of secondary lung cancers needs further evaluation. Additionally, cardiac and pulmonary toxicity needs further evaluation. Despite this, evidence supports the use of IMRT for left-sided breast lesions in which alternative types of RT cannot avoid toxicity to the heart and lungs.

Lung Cancer
Clinical Context and Therapy Purpose
The purpose of IMRT in patients who have lung cancer is to provide a treatment option that is an alternative to or an improvement on existing therapies.

The question addressed in this evidence review is: Does the use of IMRT improve the net health outcome in patients with lung cancer?

The following PICO was used to select literature to inform this review.

Populations
The relevant population of interest is individuals with lung cancer.

Interventions
The therapy being considered is IMRT. Radiotherapy is an integral component of the treatment of lung cancer; IMRT has been proposed as a method of RT that allows adequate radiation to the tumor while minimizing the radiation dose to surrounding normal tissues and critical structures.

Comparators
The following therapy is currently being used to make decisions about lung cancer: 3D-CRT.

Outcomes
The general outcomes of interest are OS, disease-specific survival, locoregional control, quality of life, and treatment-related adverse events.

Study Selection Criteria
Methodologically credible studies were selected using the following principles:  

  • To assess efficacy outcomes, comparative controlled prospective trials were sought, with a preference for RCTs.

  • In the absence of such trials, comparative observational studies were sought, with a preference for prospective studies.

  • To assess long-term outcomes and adverse events, single-arm studies that capture longer periods of follow-up and/or larger populations were sought.

  • Studies with duplicative or overlapping populations were excluded.

Review of Evidence
Systematic Reviews
Bezjak et al. (2012) conducted a systematic review that examined the evidence on the use of IMRT for the treatment of lung cancer to quantify its potential benefits and make recommendations for RT programs considering adopting this technique in Ontario, Canada.21 This review consisted of 2 retrospective cohort studies (through March 2010) reporting on cancer outcomes, which was considered insufficient evidence on which to make evidence-based recommendations. These 2 cohort studies reported on data from the same institution; the study by Liao et al (2010; reported below)22 indicated that patients assessed in their cohort (N = 409) were previously reported in another cohort involving 290 subjects, but it is not clear exactly how many patients were added in the second report. However, due to the known dosimetric properties of IMRT and extrapolating from clinical outcomes from other disease sites, reviewers recommended that IMRT be considered for lung cancer patients when the tumor is proximate to an organ at risk, where the target volume includes a large volume of an organ at risk, or where dose escalation would be potentially beneficial while minimizing normal tissue toxicity.21

Nonrandomized Comparative Studies
Liao et al. (2010) compared patients who received RT, along with chemotherapy, for inoperable non-small-cell lung cancer (NSCLC) at a single institution.22 This study retrospectively compared 318 patients who received CT plus 3D-CRT and chemotherapy from 1999 to 2004 (mean follow-up, 2.1 years) with 91 patients who received 4-dimensional CT plus IMRT and chemotherapy from 2004 to 2006 (mean follow-up, 1.3 years). Both groups received a median dose of 63 Gy. Disease endpoints were locoregional progression, distant metastasis, and OS. Disease covariates were gross tumor volume, nodal status, and histology. The toxicity endpoint was grade 3, 4, or 5 radiation pneumonitis; toxicity covariates were gross tumor volume, smoking status, and dosimetric factors. Using Cox proportional hazards models, the hazard ratios (HRs) for IMRT were less than 1 for all disease endpoints; the difference was significant only for OS. The median survival was 1.40 years for the IMRT group and 0.85 years for the 3D-CRT group. The toxicity rate was significantly lower in the IMRT group than in the 3D-CRT group. The volume of the lung receiving 20 Gy was higher in the 3D-CRT group and was a factor in determining toxicity. Freedom from distant metastasis was nearly identical in both groups. The authors concluded that treatment with 4-dimensional CT plus IMRT was at least as good as that with 3D-CRT in terms of the rates of freedom from locoregional progression and metastasis. This retrospective study found significant reductions in toxicity and improvement in survival. The nonrandomized, retrospective aspects of this study from a single center limit the ability to draw definitive treatment conclusions about IMRT.

Shirvani et al. (2013) reported on a U.S. cancer center study that assessed the use of definitive IMRT in limited-stage small-cell lung cancer treated with definitive RT.23 In this study of 223 patients treated from 2000 to 2009, 104 received IMRT and 119 received 3D-CRT. Median follow-up times were 22 months (range, 4 to 83 months) for IMRT and 27 months (range, 2 to 147 months) for 3D-CRT. In both multivariable and propensity score-matched analyses, OS and disease-free survival did not differ between IMRT and 3D-CRT. However, rates of esophagitis-related percutaneous feeding tube placements were lower with IMRT (5%) than with 3D-CRT (17%; p =.005).

Harris et al. (2014) compared the effectiveness of IMRT, 3D-CRT, or 2D-RT in treating stage III NSCLC using a cohort of patients from the Surveillance, Epidemiology, and End Results-Medicare database treated between 2002 and 2009.24 Overall survival was better with IMRT and 3D-CRT than with 2D-CRT. In univariate analysis, improvements in OS (HR, 0.90, p = .02) and cancer-specific survival (HR, 0.89, p = .02) were associated with IMRT. However, IMRT was similar to 3D-CRT after controlling for confounders in OS (HR, 0.94, p = .23) and cancer-specific survival (HR, 0.94, p = .28). On multivariate analysis, toxicity risks with IMRT and 3D-CRT were also similar. Likewise, results were similar for the propensity score-matched models and the adjusted models.

Ling et al. (2016) compared IMRT with 3D-CRT in patients who had stage III NSCLC treated with definitive RT.25 In this study of 145 consecutive patients treated between 1994 and 2014, the choice of treatment was at the treating physician's discretion but all IMRT treatments were performed in the last 5 years. The authors found no significant differences between the groups for any measure of acute toxicity (grade ≥ 2 esophagitis, grade ≥ 2 pneumonitis, percutaneous endoscopic gastrostomy, narcotics, hospitalization, or weight loss). There were no significant differences in oncologic and survival outcomes.

Chun et al. (2017) reported on a secondary analysis of a trial that assessed the addition of cetuximab to a standard chemotherapy regimen and radiation dose escalation.26 Use of IMRT or 3D-CRT was a stratification factor in the 2 x 2 design. Of 482 patients in the trial, 53% were treated with 3D-CRT and 47% were treated with IMRT, though treatment allocation was not randomized. Compared with the 3D-CRT group, the IMRT group had larger planning treatment volumes (486 mL vs. 427 mL, p =.005), larger planning treatment volume/volume of lung ratio (median, 0.15 vs. 0.13; p = .13), and more stage IIIB breast cancer patients (38.6% vs. 30.3%, p = .056). Even though there was an increase in treatment volume, IMRT was associated with less grade 3 or greater pneumonitis (3.5% vs. 7.9%, p =.039) and a reduced risk (odds ratio [OR], 0.41; 95% CI, 0.171 to 0.986; p = .046), with no significant differences between the groups in 2-year OS, progression-free survival, local failure, or distant metastasis-free survival.

Koshy et al. (2017) published a retrospective cohort analysis of patients with stage III NSCLC, comparing those treated with IMRT and with non-IMRT.27 Using the National Cancer Database, 7493 patients treated between 2004 and 2011 were assessed. Main outcomes were OS and the likelihood and effects of radiation treatment interruption, defined as a break in the treatment of 4 or more days. Overall survival for non-IMRT and IMRT patients, respectively, were 18.2 months and 20 months (p < .001) (Table 4). Median survival with and without a radiation treatment interruption was 16.1 and 19.8 months, respectively (p < .001), and IMRT significantly reduced the likelihood of a radiation treatment interruption (OR, 0.84; p = .04). The study was limited by unavailable information regarding RT planning and potential mechanisms affecting survival, and by a possible prescription bias, causing patients with better performance status to be given IMRT.

Appel et al. (2019) conducted another retrospective, single institution cohort evaluating the impact of radiation technique on pathological and clinical outcomes in 74 patients with locally advanced NSCLC managed with a trimodality strategy. Key study characteristics and results are presented in Tables 3 and 4. The 2-year overall local control rate was 81.6% (95% CI, 69% to 89.4%), disease-free survival was 58.3% (95% CI, 45.5% to 69%), and 3-year OS was 70% (95% CI, 57% to 80%). When comparing radiation techniques for these outcomes, there were no significant differences in local control (p = .94), disease-free survival (p =.33), or OS (p = .72). Grade 2 esophageal toxicity was non-significantly reduced with IMRT as compared to 3D-CRT (32% vs. 37%; p = .66). As with other studies, the retrospective design and single-center nature of this cohort make generalizability of the results to other cancer centers limited.

Table 3. Summary of Key Observational Comparative Study Characteristics 

Study Study Type Country Dates Participants Treatment Comparator FU
Koshy et al. (2017)27 Cohort U.S. 2004-2011 7493 IMRT Non-IMRT 32 mo
Appel et al. (2019)28 Cohort Israel 2012-2018 74 IMRT 3D-CRT 3.6 years (median)

3D-CRT; 3-dimensional conformal radiotherapy; FU: follow-up; IMRT: intensity-modulated radiotherapy. 

Table 4. Summary of Key Observational Comparative Study Results

Study OS Major Pathologic Response Rate Pathologic Complete Response Rate
Koshy et al. (2017)27 Months    
IMRT 20.0    
Non-IMRT 18.2    
p <.001    
Appel et al. (2019)28 2-year    
IMRT % (95% CI) 85% (60 to 95) 65.2% 34.8%
3D-CRT % (95% CI) 82% (68 to 90) 62.7% 33.3%
p .72 .83 .9

3D-CRT; 3-dimensional conformal radiotherapy; CI: confidence interval; IMRT: intensity-modulated radiotherapy; OS: overall survival.

Section Summary: Lung Cancer
For the treatment of lung cancer, no RCTs were identified that compared IMRT with 3D-CRT. Dosimetry studies have reported that IMRT can reduce radiation exposure to critical surrounding structures, especially for large lung tumors. Based on nonrandomized comparative studies, IMRT appears to produce survival outcomes comparable with those of 3D-CRT, with a reduction in adverse events.

Summary of Evidence
For individuals who have breast cancer who receive IMRT, the evidence includes systematic reviews, RCTs, and nonrandomized comparative studies. Relevant outcomes are OS, disease-specific survival, locoregional control, quality of life, and treatment-related morbidity. There is modest evidence from RCTs for a decrease in acute skin toxicity with IMRT compared with 2D-RT for whole-breast irradiation, and dosimetry studies have demonstrated that IMRT reduces inhomogeneity of radiation dose, thus potentially providing a mechanism for reduced skin toxicity. However, because whole-breast RT is now delivered by 3D-CRT, these comparative data are of limited value.

Studies comparing IMRT with 3D-CRT include 1 RCT comparing IMRT with DIBH to 3D-CRT, 2 additional RCTs comparing IMRT to 3D-CRT in women who had undergone breast-conserving surgery (with 1 RCT evaluating simultaneous vs. sequential boost therapy), 2 nonrandomized comparative studies on whole-breast IMRT, and a few studies on chest wall IMRT. These studies suggest that IMRT requires less radiation exposure to nontarget areas and may improve upon, or provide similar improvement in, clinical outcomes. The available studies on chest wall IMRT for postmastectomy breast cancer patients have focused on treatment planning and techniques. However, when dose-planning studies have indicated that RT will lead to unacceptably high radiation doses, the studies suggest IMRT will lead to improved outcomes. The evidence is sufficient to determine that the technology results in an improvement in the net health outcome.

For individuals who have lung cancer who receive IMRT, the evidence includes nonrandomized, retrospective, comparative studies. Relevant outcomes are OS, disease-specific survival, locoregional control, quality of life, and treatment-related morbidity. Dosimetry studies have shown that IMRT can reduce radiation exposure to critical surrounding structures, especially in large lung tumors. Based on nonrandomized comparative studies, IMRT appears to produce survival outcomes comparable to those of 3D-CRT, and reduce toxicity. The evidence is sufficient to determine that the technology results in an improvement in the net health outcome.

The purpose of the following information is to provide reference material. Inclusion does not imply endorsement or alignment with the evidence review conclusions.

Clinical Input From Physician Specialty Societies and Academic Medical Centers
While the various physician specialty societies and academic medical centers may collaborate with and make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

2012 Input
In response to requests, input was received from 2 physician specialty societies and 3 academic medical centers (3 reviewers) while this policy was under review in 201 2. There was a near-uniform consensus in responses that whole-breast and lung intensity-modulated radiotherapy (IMRT) is appropriate in select patients with breast and lung cancer. Respondents noted IMRT might reduce the risk of cardiac, pulmonary, or spinal cord exposure to radiation in some cancers such as those involving the left breast or large cancers of the lung. Respondents also indicated whole-breast IMRT might reduce skin reactions and potentially improve cosmetic outcomes. Partial-breast IMRT was not supported by respondents, and the response was mixed on the value of chest wall IMRT postmastectomy.

2010 Input
In response to requests, input was received from 1 physician specialty society and 2 academic medical centers (3 reviewers) while this policy was under review in 2010. Input suggested that IMRT is used in select patients with breast cancer (e.g., some cancers involving the left breast) and lung cancer (e.g., some large cancers).

Practice Guidelines and Position Statements
Guidelines or position statements will be considered for inclusion in Supplemental Information if they were issued by, or jointly by, a U.S. professional society, an international society with U.S. representation, or National Institute for Health and Care Excellence (NICE). Priority will be given to guidelines that are informed by a systematic review, include strength of evidence ratings, and include a description of management of conflict of interest.

National Comprehensive Cancer Network
Breast Cancer
Current National Comprehensive Cancer Network (NCCN) guidelines (v.4.2021) for breast cancer indicate the importance of individualizing radiotherapy (RT) planning and delivery. Computed tomography-based treatment planning is encouraged to delineate target volumes and adjacent organs at risk. Improved target dose homogeneity and sparing of normal tissues can be accomplished utilizing various "compensators such as wedges, forward planning using segments, and IMRT." Respiratory control techniques including deep inspiration breath-hold and prone positioning may be used to try to further reduce dose in adjacent normal tissues, such as the heart and lung.29 The guideline states that "the panel recommends whole breast irradiation to include breast tissue in entirety. CT-based treatment planning is recommended to limit irradiation exposure of the heart and lungs, and to assure adequate coverage of the breast and lumpectomy site." The guidelines indicate chest wall and regional lymph node irradiation may be appropriate postmastectomy in select patients but IMRT is not mentioned as a technique for irradiation in these circumstances.

Lung Cancer
Current NCCN guidelines (v.4.2021) for non-small-cell lung cancer indicate that "More advanced technologies are appropriate when needed to deliver curative RT safely. These technologies include (but are not limited to) … IMRT/VMAT [volumetric modulated arc therapy]…. Nonrandomized comparisons of using advanced technologies versus older techniques demonstrate reduced toxicity and improved survival."30

Current NCCN guidelines (v.3.2021) for small-cell lung cancer indicate that "Use of more advanced technologies is appropriate when needed to deliver adequate tumor doses while respecting normal tissue dose constraints."31 Intensity-modulated RT is included in the technologies listed. The guidelines also state that "IMRT is preferred over 3D conformal external-beam RT on the basis of reduced toxicity in the setting of concurrent chemotherapy/RT."

American Society for Radiation Oncology
Breast Cancer
In 2018, the American Society for Radiation Oncology published evidence-based guidelines on whole-breast irradiation with or without low axilla inclusion. The guidance recommended a "preferred" radiation dosage of "4000 cGy [centigray] in 15 fractions or 4250 cGy in 16 fractions."32

Lung Cancer
In 2018, the American Society for Radiation Oncology also published evidence-based guidelines on RT for lung cancer. The guidelines recommended "moderately hypofractionated palliative thoracic radiation therapy" with chemotherapy as palliative care for stage III and IV incurable non-small-cell lung cancer.33

American Society of Clinical Oncology/American Society for Radiation Oncology/Society of Surgical Oncology
Breast Cancer
In 2016, the American Society of Clinical Oncology (ASCO), American Society for Radiation Oncology, and the Society of Surgical Oncology developed a focused update of a prior ASCO guideline related to the use of post mastectomy RT.34 The Expert Panel unanimously agreed that "available evidence shows that post mastectomy RT reduces the risk of locoregional failure, any recurrence, and breast cancer mortality for patients with T1-2 breast cancer with 1 to 3 positive axillary nodes. However, some subsets of these patients are likely to have such a low risk of locoregional failure that the absolute benefit of post mastectomy RT is outweighed by its potential toxicities." Additionally, the guideline noted that "the decision to recommend post mastectomy RT requires a great deal of clinical judgment."

U.S. Preventive Services Task Force Recommendations
Not applicable

Ongoing and Unpublished Clinical Trials
Some currently ongoing and unpublished trials that might influence this review are listed in Table 5. 

Table 5. Summary of Key Trials 

NCT No. Trial Name Planned Enrollment Completion Date
Ongoing      
NCT02635009 Randomized Phase II/III Trial of Prophylactic Cranial Irradiation With or Without Hippocampal Avoidance for Small Cell Lung Cancer 392 Apr 2027
NCT01349322 A Phase III Trial of Accelerated Whole Breast Irradiation with Hypofractionation Plus Concurrent Boost Versus Standard Whole Breast Irradiation Plus Sequential Boost for Early-Stage Breast Cancer 2354 Aug 2022
NCT02003560 Accelerated Partial Breast Irradiation After Breast Conserving Surgery for Low-risk Invasive Breast Cancer: 3D Conformal Radiotherapy (3D-CRT) and Intensity Modulated Radiotherapy (IMRT) - Prospective Phase II Study 90 Mar 2024
NCT03786354 Prospective Evaluation of Shoulder Morbidity in Patients with Lymph-Node Positive Breast Cancer Receiving Regional Nodal Irradiation 60 Dec 2020
NCT01185132 A Phase III Randomized Study Comparing Intensity Modulated Planning vs 3-dimensional Planning for Accelerated Partial Breast Radiotherapy 660 Jul 2028
Unpublished      
NCT00520702 A Randomized Trial to Compare Time To Common Toxicity Criteria for Adverse Effect (CTC AEC) 3.0 Grade Treatment Related Pneumonitis (TRP) in Patients With Locally Advanced Non-Small Cell Carcinoma (NSCLC) Receiving Concurrent Chemoradiation Radiation Treated With 3-Dimensional Conformal Radiation Therapy (3D CRT, ARM 1) vs Intensity Modulated Radiation (IMRT, ARM 2) Using 4 Dimensional CT Planning and Image-Guided Adaptive Radiation Therapy (IGART) 168 Oct 2018
 
NCT01322854 Randomized Phase III Trial Comparing Intensity Modulated Radiotherapy With Integrated Boost to Conventional Radiotherapy With Consecutive Boost in Patients With Breast Cancer After Breast Conserving Surgery 502 Mar 2018
(unknown)

NCT: national clinical trial.

References:   

  1. Donovan E, Bleakley N, Denholm E, et al. Randomised trial of standard 2D radiotherapy (RT) versus intensity modulated radiotherapy (IMRT) in patients prescribed breast radiotherapy. Radiother Oncol. Mar 2007; 82(3): 254-64. PMID 17224195
  2. Pignol JP, Olivotto I, Rakovitch E, et al. A multicenter randomized trial of breast intensity-modulated radiation therapy to reduce acute radiation dermatitis. J Clin Oncol. May 01 2008; 26(13): 2085-92. PMID 18285602
  3. Shinohara E, Whaley JT. Radiation therapy: which type is right for me? Last reviewed: March 3, 2020. https://www.oncolink.org/cancer-treatment/radiation/introduction-to-radiation-therapy/radiation-therapy-which-type-is-right-for-me. Accessed June 2, 2020
  4. Jagsi R, Griffith KA, Moran JM, et al. A Randomized Comparison of Radiation Therapy Techniques in the Management of Node-Positive Breast Cancer: Primary Outcomes Analysis. Int J Radiat Oncol Biol Phys. Aug 01 2018; 101(5): 1149-1158. PMID 30012527
  5. Kaza E, Dunlop A, Panek R, et al. Lung volume reproducibility under ABC control and self-sustained breath-holding. J Appl Clin Med Phys. Mar 2017; 18(2): 154-162. PMID 28300372
  6. Coon AB, Dickler A, Kirk MC, et al. Tomotherapy and multifield intensity-modulated radiotherapy planning reduce cardiac doses in left-sided breast cancer patients with unfavorable cardiac anatomy. Int J Radiat Oncol Biol Phys. Sep 01 2010; 78(1): 104-10. PMID 20004529
  7. Dayes I, Rumble RB, Bowen J, et al. Intensity-modulated radiotherapy in the treatment of breast cancer. Clin Oncol (R Coll Radiol). Sep 2012; 24(7): 488-98. PMID 22748561
  8. Pignol JP, Truong P, Rakovitch E, et al. Ten years results of the Canadian breast intensity modulated radiation therapy (IMRT) randomized controlled trial. Radiother Oncol. Dec 2016; 121(3): 414-419. PMID 27637858
  9. Barnett GC, Wilkinson J, Moody AM, et al. A randomised controlled trial of forward-planned radiotherapy (IMRT) for early breast cancer: baseline characteristics and dosimetry results. Radiother Oncol. Jul 2009; 92(1): 34-41. PMID 19375808
  10. Barnett GC, Wilkinson JS, Moody AM, et al. Randomized controlled trial of forward-planned intensity modulated radiotherapy for early breast cancer: interim results at 2 years. Int J Radiat Oncol Biol Phys. Feb 01 2012; 82(2): 715-23. PMID 21345620
  11. Choi KH, Ahn SJ, Jeong JU, et al. Postoperative radiotherapy with intensity-modulated radiation therapy versus 3-dimensional conformal radiotherapy in early breast cancer: A randomized clinical trial of KROG 15-03. Radiother Oncol. Jan 2021; 154: 179-186. PMID 32980384
  12. Horner-Rieber J, Forster T, Hommertgen A, et al. Intensity Modulated Radiation Therapy (IMRT) With Simultaneously Integrated Boost Shortens Treatment Time and Is Noninferior to Conventional Radiation Therapy Followed by Sequential Boost in Adjuvant Breast Cancer Treatment: Results of a Large Randomized Phase III Trial (IMRT-MC2 Trial). Int J Radiat Oncol Biol Phys. Apr 01 2021; 109(5): 1311-1324. PMID 33321192
  13. Krug D, Koder C, Hafner MF, et al. Acute toxicity of normofractionated intensity modulated radiotherapy with simultaneous integrated boost compared to three-dimensional conformal radiotherapy with sequential boost in the adjuvant treatment of breast cancer. Radiat Oncol. Oct 13 2020; 15(1): 235. PMID 33050920
  14. Hardee ME, Raza S, Becker SJ, et al. Prone hypofractionated whole-breast radiotherapy without a boost to the tumor bed: comparable toxicity of IMRT versus a 3D conformal technique. Int J Radiat Oncol Biol Phys. Mar 01 2012; 82(3): e415-23. PMID 22019349
  15. Guttmann DM, Gabriel P, Kennedy C, et al. Comparison of acute toxicities between contemporary forward-planned 3D conformal radiotherapy and inverse-planned intensity-modulated radiotherapy for whole breast radiation. Breast J. Mar 2018; 24(2): 128-132. PMID 28703444
  16. Rudat V, Alaradi AA, Mohamed A, et al. Tangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: a dosimetric comparison. Radiat Oncol. Mar 21 2011; 6: 26. PMID 21418616
  17. Rastogi K, Sharma S, Gupta S, et al. Dosimetric comparison of IMRT versus 3DCRT for post-mastectomy chest wall irradiation. Radiat Oncol J. Mar 2018; 36(1): 71-78. PMID 29621872
  18. Ho AY, Ballangrud A, Li G, et al. Long-Term Pulmonary Outcomes of a Feasibility Study of Inverse-Planned, Multibeam Intensity Modulated Radiation Therapy in Node-Positive Breast Cancer Patients Receiving Regional Nodal Irradiation. Int J Radiat Oncol Biol Phys. Apr 01 2019; 103(5): 1100-1108. PMID 30508620
  19. Kivanc H, Gultekin M, Gurkaynak M, et al. Dosimetric comparison of three-dimensional conformal radiotherapy and intensity-modulated radiotherapy for left-sided chest wall and lymphatic irradiation. J Appl Clin Med Phys. Dec 2019; 20(12): 36-44. PMID 31680445
  20. Zhao Y, Zhu J, Zhang X, et al. Integrated IMRT vs segmented 3D-CRT of the chest wall and supraclavicular region for Breast Cancer after modified Radical Mastectomy: An 8-year follow-up. J Cancer. 2021; 12(5): 1548-1554. PMID 33532000
  21. Bezjak A, Rumble RB, Rodrigues G, et al. Intensity-modulated radiotherapy in the treatment of lung cancer. Clin Oncol (R Coll Radiol). Sep 2012; 24(7): 508-20. PMID 22726417
  22. Liao ZX, Komaki RR, Thames HD, et al. Influence of technologic advances on outcomes in patients with unresectable, locally advanced non-small-cell lung cancer receiving concomitant chemoradiotherapy. Int J Radiat Oncol Biol Phys. Mar 01 2010; 76(3): 775-81. PMID 19515503
  23. Shirvani SM, Juloori A, Allen PK, et al. Comparison of 2 common radiation therapy techniques for definitive treatment of small cell lung cancer. Int J Radiat Oncol Biol Phys. Sep 01 2013; 87(1): 139-47. PMID 23920393
  24. Harris JP, Murphy JD, Hanlon AL, et al. A population-based comparative effectiveness study of radiation therapy techniques in stage III non-small cell lung cancer. Int J Radiat Oncol Biol Phys. Mar 15 2014; 88(4): 872-84. PMID 24495591
  25. Ling DC, Hess CB, Chen AM, et al. Comparison of Toxicity Between Intensity-Modulated Radiotherapy and 3-Dimensional Conformal Radiotherapy for Locally Advanced Non-small-cell Lung Cancer. Clin Lung Cancer. Jan 2016; 17(1): 18-23. PMID 26303127
  26. Chun SG, Hu C, Choy H, et al. Impact of Intensity-Modulated Radiation Therapy Technique for Locally Advanced Non-Small-Cell Lung Cancer: A Secondary Analysis of the NRG Oncology RTOG 0617 Randomized Clinical Trial. J Clin Oncol. Jan 2017; 35(1): 56-62. PMID 28034064
  27. Koshy M, Malik R, Spiotto M, et al. Association between intensity modulated radiotherapy and survival in patients with stage III non-small cell lung cancer treated with chemoradiotherapy. Lung Cancer. Jun 2017; 108: 222-227. PMID 28625640
  28. Appel S, Bar J, Ben-Nun A, et al. Comparative effectiveness of intensity modulated radiation therapy to 3-dimensional conformal radiation in locally advanced lung cancer: pathological and clinical outcomes. Br J Radiol. May 2019; 92(1097): 20180960. PMID 30864828
  29. National Comprehensive Cancer Network. NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines): Breast Cancer, Version 4.2021. Updated April 28, 2021. https://www.nccn.org/professionals/physician_gls/pdf/breast.pdf. Accessed May 25, 2021.
  30. National Comprehensive Cancer Network. NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines): Non-Small Cell Lung Cancer, Version 4.2021. Updated March 3, 2021. https://www.nccn.org/professionals/physician_gls/pdf/nscl.pdf. Accessed May 24, 2021.
  31. National Comprehensive Cancer Network. NCCN Clinical Practice Guidelines in Oncology (NCCN Guidelines): Small Cell Lung Cancer, Version 3.2021. Updated March 23, 2021 https://www.nccn.org/professionals/physician_gls/pdf/sclc.pdf. Accessed May 23, 2021.
  32. Smith BD, Bellon JR, Blitzblau R, et al. Radiation therapy for the whole breast: Executive summary of an American Society for Radiation Oncology (ASTRO) evidence-based guideline. Pract Radiat Oncol. May 2018; 8(3): 145-152. PMID 29545124
  33. Moeller B, Balagamwala EH, Chen A, et al. Palliative thoracic radiation therapy for non-small cell lung cancer: 2018 Update of an American Society for Radiation Oncology (ASTRO) Evidence-Based Guideline. Pract Radiat Oncol. Jul 2018; 8(4): 245-250. PMID 29625898
  34. Recht A, Comen EA, Fine RE, et al. Postmastectomy Radiotherapy: An American Society of Clinical Oncology, American Society for Radiation Oncology, and Society of Surgical Oncology Focused Guideline Update. Pract Radiat Oncol. Nov 2016; 6(6): e219-e234. PMID 27659727

Coding Section

Codes Number Description
CPT 77301

Intensity modulated radiotherapy plan, including dose volume histograms for target and critical structure partial tolerance specifications

  77338

Multi-leaf collimator (MLC) device(s) for intensity modulated radiation therapy (IMRT), design and construction per IMRT plan

  77385

Intensity modulated radiation treatment delivery (IMRT), includes guidance and tracking, when performed; simple (new code 01/01/15) 

  77386

complex (new code 01/01/15) 

HCPCS G6015

Intensity modulated treatment delivery, single or multiple fields/arcs, via narrow spatially and temporally modulated beams, binary, dynamic MLC, per treatment session (new code 01/01/15) 

  G6016

Compensator-based beam modulation treatment delivery of inverse planned treatment using 3 or more high resolution (milled or cast) compensator, convergent beam modulated fields, per treatment session (new code 01/01/15)

ICD-10-CM (effective 10/01/15) C34.00-C34.92

Malignant neoplasm of bronchus and lung code range 

  C50.011-C50.929

Malignant neoplasm of breast code range

ICD-10-PCS (effective 10/01/15)  

ICD-10-PCS codes are only used for inpatient services. There is no specific ICD-10-PCS code for this therapy. 

  DM000ZZ, DM001ZZ, DM002ZZ, DM010ZZ, DM011ZZ, DM012ZZ

Radiation oncology, breast, beam radiation, codes by anatomical location (left or right breast) and modality (photons < 1 MeV, photons 1-10 MeV and photons > 10 MeV) 

  DB020ZZ, DB021ZZ, DB022ZZ Radiation oncology, respiratory system, beam radiation lung, codes by modality (photons < 1 MeV, photons 1-10 MeV and photons > 10 MeV)
Type of Service    
Place of Service    

Procedure and diagnosis codes on Medical Policy documents are included only as a general reference tool for each policy. They may not be all-inclusive.

This medical policy was developed through consideration of peer-reviewed medical literature generally recognized by the relevant medical community, U.S. FDA approval status, nationally accepted standards of medical practice and accepted standards of medical practice in this community, Blue Cross and Blue Shield Association technology assessment program (TEC) and other non-affiliated technology evaluation centers, reference to federal regulations, other plan medical policies and accredited national guidelines.

"Current Procedural Terminology© American Medical Association. All Rights Reserved." 

History From 2014 Forward     

08/23/2022 Annual review, no change to policy intent

08/12/2021

Annual reivew, no change to policy intent. Updating rationale and references. 

08/05/2020 

Annual review, no change to policy intent. Updating description, rationale and references. 

08/01/2019 

Annual review, no change to policy intent. Updating references. 

08/15/2018 

Annual review, no change to policy intent. Updating coding section of guidelines, background, rationale and references. 

10/18/2017 

Interim review, removing "left side" criteria related to breast cancer use of this technology. The policy is now neutral as to the right or left side use for breast cancer treatment. No other changes made. 

08/15/2017 

Annual review, no change to policy intent. Updating background, description, guidelines, rationale and references. 

08/02/2016 

Annual review, no change to policy intent. 

08/26/2015 

Annual review, no change to policy intent. Updated title, background, description, guidelines, rationale and references. Added coding.

08/06/2014

Annual review. Added policy verbiage to indicate this is not medically necessary if the stated criteria is not met. Added related policies. Updated guidelines, rationale and references. No change to policy intent